PENGARUH LAMA PENUNDAAN PEMBUATAN SERUM TERHADAP PEMERIKSAAN KADAR SGOT DAN SGPT DI RS ASSUYUTHIYYAH PATI
Kata Kunci:
Lama Penundaan, Sgot, SgptAbstrak
Latar Belakang: Laboratorium klinik berperan penting dalam diagnosis penyakit, termasuk pemeriksaan fungsi hati melalui pengukuran kadar SGOT (Serum Glutamic Oxaloacetic Transaminase) dan SGPT (Serum Glutamic Pyruvic Transaminase). Kualitas pemeriksaan sangat dipengaruhi oleh pengendalian mutu di tahap pra-analitik, di mana kesalahan penanganan spesimen dapat mempengaruhi hasil. Penundaan dalam pembuatan serum, terutama ketika lokasi pengambilan sampel jauh atau terbatasnya fasilitas, menjadi masalah umum. Berbagai faktor, seperti metabolisme sel, suhu, dan paparan sinar, memengaruhi stabilitas enzim AST dan ALT, sehingga dapat mengurangi akurasi hasil. Penelitian ini bertujuan untuk mengevaluasi pengaruh lama penundaan pembuatan serum terhadap pemeriksaan kadar SGOT dan SGPT dengan tiga perlakuan waktu (0, 60, dan 90 menit) pada sampel pasien. Metode: Metodologi yang digunakan dalam penelitian ini adalah kuantitatif dengan pendekatan One Group Pretest-Postest Design. Data diperoleh melalui pengukuran kadar SGOT dan SGPT kemudian dianalisi untuk melihat adanya pengaruh penundaan pembuatan serum. Hasil: Hasil uji analisis Anova pemeriksaan SGOT 0 menit dengan penundaan 60 menit didapatkan F hitung sebesar 9,333 dan nilai ρ value 0,018 kurang dari 0,05 maka hasil tersebut dapat disimpulkan bahwa terdapat perbedaan lama penundaan 0 menit dengan 60 menit pada pemeriksaan kadar SGOT di RS Assuyuthiyyah Pati. Hasil uji analisis Anova pemeriksaan SGPT 0 menit dengan penundaan 60 menit didapatkan F hitung sebesar 5,444 dan nilai ρ value 0,024 kurang dari 0,05 maka hasil tersebut dapat disimpulkan bahwa terdapat perbedaan lama penundaan 0 menit dengan 60 menit pada pemeriksaan kadar SGPT di RS Assuyuthiyyah Pati. Kesimpulan: Hasil penelitian adanya peningkatan SGOT dan SGPT dengan penundaan 0, 60 dan 90 menit dapat dipengaruhi suhu penympanan dan suhu ruang.
Background: Clinical laboratories play a crucial role in disease diagnosis, including liver function tests through the measurement of SGOT (Serum Glutamic Oxaloacetic Transaminase) and SGPT (Serum Glutamic Pyruvic Transaminase) levels. Test quality is significantly influenced by pre-analytical quality control, where specimen handling errors can impact results. Delays in serum preparation, particularly when sampling locations are remote or facilities are limited, are a common problem. Various factors, such as cell metabolism, temperature, and light exposure, affect the stability of AST and ALT enzymes, thereby reducing the accuracy of results. This study aimed to evaluate the effect of the length of serum preparation delay on SGOT and SGPT levels in patient samples using three time treatments (0, 60, and 90 minutes). Methods: This study employed a quantitative methodology with a One Group Pretest-Posttest Design. Data were obtained through SGOT and SGPT measurements and then analyzed to determine the effect of the serum preparation delay. Results: The ANOVA analysis of the 0-minute SGOT test with a 60-minute delay yielded an F-value of 9.333 and a ρ-value of 0.018, less than 0.05. It can be concluded that there is a difference in the 0-minute and 60-minute delays in SGOT level testing at Assuyuthiyyah Hospital, Pati. The ANOVA analysis of the 0-minute SGPT test with a 60-minute delay yielded an F-value of 5.444 and a ρ-value of 0.024, less than 0.05. It can be concluded that there is a difference in the 0-minute and 60-minute delays in SGPT level testing at Assuyuthiyyah Hospital, Pati.
Conclusion: The results of this study indicate that the increase in SGOT and SGPT with delays of 0, 60, and 90 minutes can be influenced by storage temperature and room temperature. This is an open accest article under the CC BY-SA licence.



